top of page

APPLICATION · PASSIVE COOLING & SHADING

Window Heat Flux Sensors for Passive Cooling & Automated Shading Control

Measure whether a window is gaining or losing heat, directly at the glass. That signal tells a shade when to deploy and shows what a blind or passive cooling strategy actually saves.

FluxTeq PHFS-01e thin-film heat flux sensor for window measurements

2 studies

below measured window heat flux with FluxTeq PHFS sensors

54–78%

lower window solar heat gain with heat-flux-based shade control (Energy and Buildings, 2022)

0 W/m²

the control point where a window switches between heat gain and heat loss

From $235

per PHFS-01e sensor

RESEARCH SUMMARIZED BELOW WAS PUBLISHED IN

Energy and Buildings  ·  Journal of Building Engineering  ·  Applied Energy

What window and shading researchers measure

Windows are often the weakest part of the building envelope: solar heat gain in hot weather, heat loss in cold weather. A heat flux sensor on the glass shows which way heat is moving and how much, a direct thermal signal that light and temperature sensors cannot give without climate-specific setpoints.

Window heat gain and loss

 

Whether heat is entering or leaving through the glass, and how much.

Automated shading control

 

A heat flux value near 0 W/m² marks the switch between gain and loss: a physical control point for shades.

Blind and shade performance

 

How much a blind or shade reduces heat flow through the window.

In-situ window U-value

 

Heat flux with glass and air temperatures gives the U-value of an installed window.

Passive cooling and ventilation

 

Verify shading and night ventilation strategies with measured heat flow.

Energy model validation

 

Measured window heat flux to check building energy simulations.

Recommended products

PHFS-01e thin film heat flux sensor

PHFS-01e

 

Thin heat flux sensor for direct window surface measurements.

 

$235    View sensor →

large area PHFS-09e heat flux sensor

PHFS-09e

 

Large-area sensor for window U-value and blind performance testing.

 

$420    View sensor →

FluxTeq FluxDAQ+ heat flux and thermocouple data logger

FluxDAQ+

 

Multi-channel heat flux and temperature logging for long-term studies.

 

$670    View logger →

Published Papers

In published research

The studies below were conducted by independent researchers. FluxTeq did not design, perform or validate the experiments. They are shown as examples of how FluxTeq sensors and DAQ systems have been used in passive cooling and shading research.

ENERGY AND BUILDINGS · 2022

PEER-REVIEWED JOURNAL

 

Direct Heat Flux Sensing for Window Shading Control in Passive Cooling Systems

 

MEASURED WITH

PHFS-01e

 

Read the full paper →

The study. Tested whether heat flux measured at the window surface is a better control signal for operable shades than illumination, solar radiation, air temperature or time-of-day schedules.

 

How heat flux was measured. FluxTeq PHFS-01e sensors were mounted on the interior surfaces of double-glazed east-, south- and west-facing windows at the University of Oregon. The signals were recorded with Arduino-based electronics, filtered, and used to simulate shading control in EnergyPlus.

 

Reported result. With 0 W/m² as the control threshold, filtered heat-flux-based control reduced window solar heat gain by 54–78% across six contrasting climates, comparable to or better than established illumination- and solar-radiation-based controls.

window automated shading phfs-01e passive cooling shading heat flux sensor

JOURNAL OF BUILDING ENGINEERING · 2025

PEER-REVIEWED JOURNAL

 

In-Situ Testing and Numerical Study of Thermal Performance of Blind Systems in a Cold Climate Zone

 

MEASURED WITH

PHFS-09e

 

Read the full paper →

The study. Measured how internal blinds change heat loss through double-pane windows in an office at the University of Alberta in Edmonton, with shades fully open, half open and fully closed, and validated a CFD model against the measurements.

 

How heat flux was measured. FluxTeq PHFS-09e large-area sensors measured heat flux through the windows, with their integrated Type-T thermocouples reading glass temperature. Data were collected every 15 seconds and averaged for U-value calculations following ISO 9869-style methods.

 

Reported result. Fully closed shades reduced energy loss by 11.25%, and half-open shades by 5.34%.

passive cooling thermal shading phfs-09e heat flux sensor

APPLIED ENERGY · 2023

PEER-REVIEWED JOURNAL · RELATED RESEARCH

 

Performance, Robustness, and Portability of Imitation-Assisted Reinforcement Learning Policies for Shading and Natural Ventilation Control

 

CONTROL SIGNAL

Window surface heat flux

 

Read the full paper →

The study. Developed a data-driven controller for shading, window openings and movable insulation in residential building simulations, using imitation-assisted reinforcement learning.

 

The role of heat flux. Window surface heat flux is one of the controller’s observations. The authors cite earlier work showing that it indicates net window heat gain or loss independent of space, orientation or climate, and note that low-cost sensors and filtering make it an affordable control input.

 

Reported result. The policies reduced simulated late-spring space-conditioning loads by at least 40% in 24 climatically diverse cities.

ai window shading diagram passive cooling heat flux sensor

APPLIED ENERGY · 2022

PEER-REVIEWED JOURNAL · RELATED RESEARCH

 

Improving the Passive Survivability of Residential Buildings During Extreme Heat Events in the Pacific Northwest

 

TOPIC

Shading and natural ventilation control

 

Read the full paper →

The study. Used EnergyPlus simulations to test how shading, natural ventilation and fan-assisted ventilation could have improved indoor conditions in multifamily apartments during the June 2021 Pacific Northwest heat wave.

 

Reported result. In Portland, integrated shading and natural ventilation eliminated all hours above the “danger” heat-index threshold during the three-day event, lowered peak indoor air temperature by about 14 °C (25 °F), and reduced active cooling loads by up to 80%.

 

Why it is here. Control timing drove the result: shading during direct sun, ventilation when outdoor air was cooler than indoor air. That is the decision a window heat flux signal is used for in the studies above.

Common questions

 

Why control shades with heat flux instead of light or temperature?

Heat flux measures the heat actually passing through the window. A value near 0 W/m² marks the change between heat gain and heat loss, so the same threshold works across orientations, seasons and climates. Light and temperature sensors usually need site-specific setpoints.

 

Where does the sensor go?

On the interior surface of the glass. The studies above mounted PHFS-01e sensors on double-glazed windows and PHFS-09e sensors on double-pane office windows.

 

Can I measure the U-value of an installed window?

Yes. Heat flux through the glass, with the glass and air temperatures, gives an in-situ U-value. The PHFS-09e has an integrated Type-T thermocouple for the surface temperature.

 

Can the sensor be built into a shading product?

Yes. FluxTeq supplies sensors in volume and makes custom sizes. The PHFS-OEM is $70 per sensor with a minimum order of four.

 

Tell us the window, shade or control system you are testing. We will suggest a setup.

bottom of page