top of page

THIN-FILM THERMOCOUPLE ARRAYS

Thin-Film Thermocouple Arrays for Multi-Point Surface Temperature

Map temperature across a surface with one flexible sheet.

Several Type-T foil junctions on a single polyimide sheet, each at a fixed, known position. Peel, stick and connect: one part replaces a handful of loose thermocouples, and every test measures the same locations.

FluxTeq thin-film foil thermocouple array on a flexible polyimide sheet

Why use a thermocouple array

Repeatable positions

Junction spacing is fixed when the array is made, so every unit and every test measures the same points.

Thin and unobtrusive

Built like the FTC foil thermocouple: 0.004 in (102 microns) of polyimide film that barely disturbs the surface it measures. Available with or without an adhesive backing.

Faster to install

One sheet to place and one set of leads to route, instead of taping down thermocouples one at a time.

Thin-film thermocouple array for surface temperature mapping

Where arrays are used

• Cold plates and liquid cooling: map temperature across a plate or heat sink face

• Battery cells and packs: follow gradients across a cell face during cycling

• Electronics and enclosures: find hot spots on boards, housings and power devices

• Panels and building materials: surface temperature at several points on one sample

• Heated or cooled tooling: check uniformity across a platen or mold

How to order

1. Send a sketch

The outline, the number and position of junctions, the lead length, and adhesive or no adhesive.

2. Get a quote

Price per array, the one-time design and tooling charge, the minimum quantity and the lead time.

3. Receive your arrays

Built to your layout and ready to connect to any Type-T thermocouple input, including FluxTeq DAQ systems.

Typical construction

 

Thermocouple type  T

Encapsulation  Polyimide (Kapton)

Thickness  0.004 in (102 microns) without adhesive; 0.005 in (127 microns) with adhesive

Operating temperature  0 to 200 °C (32 to 400 °F)

Wire leads  Fluoropolymer-insulated 30 AWG stranded Type-T wire, 24 in (0.6 m) standard

Layout  Made to your drawing

Pricing  Custom quote

Thermocouple array questions

 

What is a thermocouple array?

A set of thermocouple junctions built into one sheet at fixed positions, used to map temperature across a surface instead of at a single point.

 

Can I get a custom shape or junction spacing?

Yes. FluxTeq thermocouple arrays are designed to your drawing, including the outline, junction locations and lead length.

 

How thin is a thermocouple array?

Arrays use the same thin-film polyimide construction as the FTC foil thermocouple: 0.004 in (102 microns) thick without adhesive.

 

What reads a thermocouple array?

Any Type-T thermocouple input, including FluxTeq heat flux and thermocouple DAQ systems.

 

Tell us your layout

Send a sketch or drawing and we will reply with a quote and lead time.

bottom of page